INSTALLATION
NG
LP
INLET GAS PRESSURE
MAX 1/2 PSIG (3.5 KPA)
NG
LP
NG
LP
INLET GAS PRESSURE
MAX 1/2 PSIG (3.5 KPA)
NG
LP
Fuel
Selector
Knob
Fuel
Selector
Knob
Hex Plug
Hex Plug
Figure 5 - Settings for Natural Gas
Selection
Figure 6 - Settings for Propane/LP Gas
Selection
Gas Connection Fitting
Gas Connection Fitting
Gas Selection
This appliance is factory
preset for propane/LP gas.
No changes are required for
connecting to propane/LP.
Only a qualified installer or
service technician can perform
gas selection and connecting to
gas supply.
CAUTION: Two gas line in-
stallations at the same time are
prohibited. The access plate
to the simple switching means
shall not be opened while the
heater is in operation.
CAUTION: To avoid gas
leakage at the inlet of regulator,
a qualied installer or service
technician must use supplied
hex plug with sealant.
WARNING: Do not attempt to
access or change the setting of
the fuel selection means.
Access to and adjustment of the fuel selection
means must only be performed by a qualied
service person when connecting this appli-
ance to a specied fuel supply at the time of
installation.
Change of the selector setting to other than the
fuel type specied at the time of installation could
damage this appliance and render it inoperable.
The installer shall replace the access cover
before completing the installation and operat-
ing this appliance.
For changing from propane to
natural gas supply:
1. Remove bottom screw from cover plate
located on right side of heater (see Figure
14, page 15). Rotate to expose fuel selec-
tion device.
2. For NATURAL GAS, press in knob using
a at screwdriver with a blade with thick-
ness of a quarter and turn knob clockwise
until the knob locks into the NG po-
sition (see Figure 5). Fuel selection device
must be locked in the NG position. Do not
operate heater between locked positions!
3. Rotate and close cover over fuel selection
device and reinstall screw.
4. Remove hex plug (with wrench provided)
from natural gas inlet of regulator (see
Figure 5). Install gas line into NG inlet of
regulator. Use thread sealant to assure
there are no leaks.
For changing from natural gas
supply to propane supply:
1. Remove bottom screw from cover plate
located on back of heater (see Figure 14,
page 15). Rotate to expose fuel selection
device.
2. For propane gas, press in knob using a at
screwdriver with a blade the thickness of
a quarter and turn knob counterclockwise
until the knob locks into the LP posi-
tion (see Figure 6). Fuel selection device
must be locked in the LP position. Do not
operate heater between locked positions.
3. Rotate and close cover over fuel selection
device and reinstall screw.
4. Remove hex plug (with wrench provided)
from propane/LP gas inlet of regulator
(see Figure 6). Install gas line into LP inlet
of regulator. Use thread sealant to assure
there are no leaks.