11
Figure 7 - Minimum mantel
clearances when using hood
Figure 8- Minimum replace
clearances if installed at oor level
Combustible Material
14” Min
Noncombustible Material
Figure 9 - Minimum replace
clearances above combustible ooring
Combustible Material
5” Min
Hearth
Log set
18” Models
Top of
Fireplace
Opening
Underside of
Mantel Shelf
All minimum
distances are in
inches
Mantel Shelf
Minimum Non-
Combustible Material
Distances to Under-
side of Mantel
Minimum Non-
Combustible
Material
Height
INSTALLING DAMPER CLAMP ACCESSORY
FOR VENTED OPERATION
NOTE: When used as a vented heater, appliance must be
installed only in a solid-fuel burning replace with a working ue
constructed of noncombustible material. You may use this heater
as a vented product. There are three reasons for operating your
heater as a vented model:
1. The replace does not meet the clearance requirements for
vent-free operation.
2. State or local codes do not permit vent-free operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you must perma-
nently open chimney ue damper. You must install the damper
clamp accessory (not provided). This will insure vented operation
(see Figure 10). The damper clamp will keep damper open. Instal-
lation instructions are included with clamp accessory.
See chart below for the minimum permanent ue opening you
must provide. Attach damper clamp so the minimum permanent
opening will be maintained at all times.
Chimney
Height (ft.)
Minimum Permanent
Flue Opening (sq. in)
6’ to 15’ 39 sq inches
15’ to 30’ 29 sq inches
Area of Various Standard Round Flues
Diameter (in.) Area (sq. in.)
5” 20 sq inches
6” 29 sq inches
7” 39 sq inches
8” 51 sq inches
Figure 10 - Attach Damper to Fireplace
Damper
Damper Clamp
Damper