A. Clearance from the side of the replace opening to any combustible material and wall should follow diagram in
Figure 4.
B. Clearance from the top of the replace opening to the ceiling must not be less than 42 inches.
MINIMUM NONCOMBUSTIBLE MATERIAL CLEARANCE
If Not Using Mantel
You must have noncombustible material(s) above the replace opening. Noncombustible materials (such as slate, mar-
ble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it, such as
a noncombustible replace hood accessory. See Figure 5 next page for minimum clearance requirements.
WARNING: Seal any fresh air vents or ash clean-out doors located on the oor or wall of replace to prevent
drafting caused by pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney ue damper.
CAUTION: This heater creates warm air currents. These currents move heat to wall surface next to heater. Install-
ing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke,
aromatic candles, cleaning uids, oil or kerosene lamps, etc.) in the air exist may discolor walls.
NOTICE: State or local codes may only allow operation of this appliance in a vented conguration. Check your
state or local codes.
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating
system. Do not install this heater as your primary heat source. If you have a central heating system you may run
the system’s circulating blower while using the heater. This will help circulate the heat throughout the house. In the
event of power outage, you can use this heater as your primary heat source.
IMPORTANT: Vent-free heaters add moisture to the air. Although this is benecial, installing heater in rooms
without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and
Ventilation, pages 5 through 7.
WARNING: This appliance is designed
for installation in only a solid-fuel burn-
ing masonry or UL 127 factory-built
replace or in a listed ventless rebox
enclosure. Exception: DO NOT install
LOG SIZING REQUIREMENTS
Log Size Minimum Firebox Size
High Depth Front Width Rear Width
PCD18T 20 in. 13 in. 29 in. 23 in.
PCD24TD 20 in. 14 in. 30 in. 24 in.
PCD24M 20 in. 14 in. 30 in. 24 in.
CHECK GAS TYPE
Make sure your gas supply is correct for
your log set. If supply is not correct, do
not install heater. Call dealer where you
purchased heater for proper gas log set.
this appliance in a factory-built replace
that includes instructions stating it has
not been tested or should not be used
with unvented gas logs.
MINIMUM CLEARANCE FOR SIDE
Combustible Material, Side Wall, and
Ceiling.
Figure 4 - Minimum Clearance for Combustible to Wall